Entry  Tue Aug 12 13:49:24 2025, Mary, Update, , point absorber and coated aperture in A# Aug12.pdf
 
Entry  Tue Aug 12 13:46:56 2025, Christina, Update, ,  3.png3-1.png
 
Entry  Tue Aug 12 13:32:43 2025, Liu, Update, Interferometer Simulations,  Screenshot_2025-08-12_at_1.31.11_PM.pngScreenshot_2025-08-12_at_1.31.17_PM.png
Differences in Fused Silica parameters.
Entry  Tue Aug 12 13:28:00 2025, Tyler, Update, TCS, RH Fenicsx v. HV Profile_comparison.png1W_diff.png50W_diff.png
 
Entry  Tue Aug 12 12:35:19 2025, Tyler, Update, , CyMAC ADC Update CSD_magnitude.pngchi_sq.png
[Christina, Ma, Tyler]

 Updated CyMAC measurement, comparing 260 hrs of measurement time vs. 405 hrs.
Entry  Tue Aug 12 12:16:21 2025, Liu, Update, Interferometer Simulations, Multi-ring FROSTI optimization for A# Update.pdf
Multi-ring FROSTI optimization for A# with static polishing
Entry  Mon Aug 11 22:19:50 2025, Christina, Update, TCS, Red Pitaya Data Streaming 3.png3-1.png
 [Ma, Tyler, Christina] 

 This past week, we were able to set up the data streaming for continuous acquisition to the PCs, and can conduct the initial tests now. We were
able to do this by:


 Installing the correct OS ecosystems to each Red Pitaya 
 Installing the terminal streaming client 
Entry  Wed Aug 6 16:31:37 2025, Xuesi Ma, Update, ,  941.jpg942.jpg943.jpg945.jpg946.jpg

    Date and Time: Around 4:20 PM on Auguest 6, 2025
    Location and Temperature:
    
        Back of the room 1119, around the working station: 90.2 °F
        Front of the room 1119, around the doorway:
Entry  Tue Aug 5 12:21:04 2025, Liu, Update, Interferometer Simulations, FROSTI A# optimization Update.pdf
A# multi-ring FROSTI optimization
Entry  Tue Aug 5 11:25:17 2025, Mary, Update, , point absorber and coated aperture in A# point_absorber_A#.pdf
Simulating how point absorber defects on Advanced LIGO mirrors affect cavity performance by modeling a 4km LIGO-like arm cavity with a point absorber
fixed at 5cm off-center on the ITM. In this simulation, displaced the laser beam across a 21×21 grid while calculating the deformation, then measuring
the resulting power loss in the cavity (~283W circulating power).
Entry  Thu Jul 31 14:26:58 2025, Xuesi Ma, Update, ,  2025-08-07_cleanroom_chart.png
[Tyler, Ma, Christina, Maple, Cece, Mary, Pooyan, Audrey]
We started by cleaning outside of the cleanroom wiping down the cable channel and working our way down while taking the pre-cleaning measurement.
We then stated wiping down the inside of clean room and vacuumed, mopped the outside of the cleanroom. Finally, we vacuumed, mopped, and wiped down the
Entry  Tue Jul 29 12:30:00 2025, Christina, Update, TCS, 260 hour ADC update CSD_06_28_25_270hr.png
 [Ma, Christina, Tyler] 

ADC CyMAC 260 hr, 8192Hz sampling rate channels V3 and Vref6
Entry  Tue Jul 29 11:45:19 2025, Maple, Update, TCS, Meeting update Maple_TCS_update_jul_29.pdf
 
Entry  Tue Jul 29 11:27:57 2025, Liu, Update, Interferometer Simulations, Multi-ring FROSTI optimization for A# Update.pdfscene-export-temp.htmlscene-export-deformation.html
 
Entry  Tue Jul 22 12:20:29 2025, Christina, Update, TCS,  PSDch0-15.pngCSD2hz_16hz.png
 [Ma, Christina, Tyler] 
 Figure 1 shows the following PSDs for channels 0-15 from the 14 hour test. Figure 2 shows the reduced chi squared and
CSD plots for both the 2 Hz and 16 Hz resolutions.
Entry  Tue Jul 15 13:13:48 2025, Christina, Update, TCS, Photodetector optical post assembly pdreassembly.png
 
Entry  Tue Jul 15 11:47:53 2025, Xuesi Ma, Infrastructure, ,  20250701_165118.jpg20250701_165200.jpg20250701_165329.jpg20250701_165246.jpg

    Date and Time: Around 4:50 PM on July 1, 2025
    Location and Temperature:
    
        Back of the room 1119, around the working station: 85.7 °F
        Front of the room 1119, around the doorway:
Entry  Tue Jul 15 10:40:23 2025, Christina, Update, TCS,  rpon.png
 [Christina, Ma, Tyler] 

 Yesterday, Ma and I started taking data for the PSD/CSD measurements while the photodetectors and one of the heater
elements are on (8) and are using the Red Pitaya to compare it to the data we took for the same measurements on the CyMAC. It will be finished Wednesday
morning, and then we plan on starting to take additional recordings in order to conduct the same type of comparison for the dark noise measurements. 
Entry  Mon Jul 14 23:50:22 2025, Tyler, Update, , Cymac ADC update cymac_ADC_PSDs.pdfch35_ADC_comps.pdf
 I've been looking into the performances of individual channels on the Cymac by computing their individual PSDs and corresponding CSDs that show their
noise relation to each other. It appears some channels do have lower noise floors than others, and some combinations of these actually  do  perform
similar to the Red Pitaya (showing below the CSD between CHs 3 and 5), although it doesn't look like it's much of an improvement. The best method as of
Entry  Mon Jul 14 20:45:20 2025, Luke , Summary, Cleanroom, HEPA filter performance metrics  
[Luke, Luis]

We’ve been looking into methods for evaluating the performance of the HEPA filters in the clean room. Measuring flow rate appears to be
a promising approach, since the filter manual specifies a recommended minimum of 70 ft/min.
Entry  Thu Jul 10 16:41:18 2025, Christina, Update, TCS,  2994921113032912040.JPG4717009101108174053.JPG5782646701589802125.JPG
 [Christina, Ma, Tyler] 

 Pomona Box completed and is now on the server rack in 1119. Additionally, the photodetectors were connected to the
box and set up in front of the heater elements. 
Entry  Tue Jul 8 12:15:04 2025, Tyler, Update, TCS, CyMAC ADC Noise Update ADC_comps.pdf
[Tyler, Christina, Ma, Mary]

Below is attached the ADC noise floor of two CyMAC channels vs the Red Pitaya.
The frequency resolution of these RIN spectra are 16 Hz, with N_meas = 19,308,426 for the CyMAC, and N_meas = 263,024.
Entry  Tue Jul 8 11:46:55 2025, Maple Matzner, Update, TCS, Update on SURF progress for Jul 8 Maple_TCS_update_jul_8.pdf
 
Entry  Mon Jul 7 17:44:04 2025, Tyler, Update, General, Lab Organization IMG_1874.jpgIMG_1872.jpgIMG_1871.jpg
[Tyler, Pooyan, Ma, Cece, Luke, Luis, Christina, Maple]

After acquiring some new equipment for the labs, a few of us spent time on Thursday and Friday
sorting through everything and storing them into their appropriate places. New vacuum parts, power supplies, cables, and much more were included. The rooms
are now ready for the lab tours commencing Tuesday afternoon.
Entry  Mon Jul 7 16:39:18 2025, Christina, Update, TCS, Pomona Box Drawings pbdwg1.PDFpbdwg2.pdf
 Below are the drawings for the pomona box modifications 
Entry  Tue Jul 1 13:41:36 2025, Xuesi Ma, Update, ,  
[Ma, Liu]
 Slides
Entry  Tue Jul 1 12:39:42 2025, Tyler, Update, TCS, A# FROSTI Profile Optimization Update 
[Tyler, Liu]

 Slides
Entry  Tue Jul 1 11:04:00 2025, Christina, Update, TCS, FROSTI Reconstruction II IMG_4042.png
 [Ma, Tyler, Christina] 

 Finished external reconstruction of the FROSTI by installing all the pins to the 2 DB 25 connectors. To ensure everything
was operating correctly, we did electrical testing by testing continuity and by checking each of the heater elements' RTD and power resistance values and
comparing them to what was tabulated in January. Additionally, we organized the wires and added the stands. 
Entry  Fri Jun 27 15:38:22 2025, Christina, Update, TCS, FROSTI Reconstruction IMG_4009.png
 [Tyler, Ma, Christina, Luke] 

 We threaded the wiring of the heater elements through the reflective surfaces and were able to attach each piece with the Macor spacers and
connect both sides. We used the guide rails and screws to ensure proper alignment. The only necessary step left is to add the additional external screws
Entry  Wed Jun 25 15:44:47 2025, Luke , Update, Cleanroom, Cleanroom cleaning parttical_count_6-25-25.png
[Luke, Luis, Tyler, Ma, Christina, Maple]
We started by cleaning outside of the cleanroom wiping down the cable channel and working our way down. We replaced the air filter in the HEPA
filter with what seemed to be the last one in storage. We then vacuumed outside, before wiping down the inside of the cleanroom. We then vacuumed, mopped,
Entry  Tue Jun 24 13:47:58 2025, Liu, Update, Interferometer Simulations, Alternative FROSTI A# optimization approach Update.pdf
Alternative FROSTI A# optimization approach
Entry  Tue Jun 24 12:45:16 2025, Tyler, Update, General, Updated ADC spectra csd_spec.pngchi_sq.png
[Tyler]

Updated ADC noise spectra measurements using diaggui. 

 NOTE: Will update plots with proper axes
Entry  Tue Jun 24 11:50:15 2025, Xuesi Ma, Update, ,  resistance_vs_time_all_channels_channel_switch.jpgresistance_vs_time_all_channels_channel_switch_one_cycle_before.jpgresistance_vs_time_all_channels_channel_switch_one_cycle_after.jpgresistance_vs_voltage.jpg



    
    
    Heater
Element Resistance Test Results
    
        .heater-test-container {
            font-family: Arial, sans-serif;
            line-height:
1.6;
            max-width: 800px;
            margin: 20px auto;
            padding: 20px;
            color: #333;
        }
        .heater-test-container
Entry  Tue Jun 17 12:46:47 2025, Tyler, Update, Electronics, CyMAC ADC Noise cymac_v_rp_csds.pdfchi_sq_cymac_v_rp.pdf
Below are results from power spectra measurements of the CyMAC ADC, computed form 30 hours of time series data, compared to the performance of the Red Pitaya.
The frequency resolution for the initial Cymac CSD is 2 Hz, and 216,000 spectra measurements are averaged together. As of now, it still looks like we haven't
reached the correlated noise floor of the CyMAC. We have a few days worth of data to take from, so I'll look into using a longer period of time.
Entry  Tue Jun 17 12:22:43 2025, Xuesi Ma, Update, ,  12x



    
    
    CYMAC
Remote Control Cable Documentation
    
        .connector {
            background-color: #f8f9fa;
            border-left: 4px solid
#3498db;
            padding: 10px 15px;
            margin: 15px 0;
        }
        .pin-table {
            width: 100%;
            border-collapse:
Entry  Wed Jun 11 16:33:45 2025, Pooyan, Update, Computers, Luke's ray tracing hosting 

Hosted Lukes model on Chimay. It's available at https://richardsonlab.ucr.edu/real-time-frosti
The
sourcecode is at Github. It is clones at /var/www/html/real-time-frosti, and
this is the block added to nginx config file at /etc/nginx/sites-available/default :
Entry  Wed Jun 11 16:19:37 2025, Pooyan, Update, CDS, CDS update Screenshot_20250611_154834.pngf3k.pdf

Fast channels recorded to .gwf frame files

Had to add a DAQ Channels block to the c1msc model for those channel to be recorded in the
.gwf frame files. The block is in the CDS_PARTS, and I just had to copy it to our model. Here is the example text for the channels:
Entry  Tue Jun 10 12:13:00 2025, Xuesi Ma, Update, ,  resistance_vs_voltage.pdfresistance_vs_voltage_element_5.pdfresistance_vs_time_all_channels_all_time_RV.pdf

  By measuring the resistance of the ladder, I obtained a graph of resistance as a function of voltage.
  All the heater elements behave consistently, showing only a small standard deviation.
  However, heater element 5 shows a significantly larger standard deviation.
Entry  Tue Jun 10 12:11:14 2025, Pooyan, Update, CDS, CDS update 

The MEDM models issue was fixed. The issue was that building the c1msc model alone was not enough and we had to re-build the c1iop as well, although
no changes has been made to the c1iop. Added a note in the wiki on this for future reference.
For
writing the fast channels to the frame files, our CDS system should have a GDS broadcaster. I followed this
Entry  Tue Jun 3 13:16:53 2025, Xuesi Ma, Infrastructure, ,  928.jpg929.jpg931.jpg930.jpg932.jpg

    Date and Time: Around 3:50 PM on June 2, 2025
    Location and Temperature:
    
        Back of the room 1119, around the working station: 86 °F
        Front of the room 1119, around the doorway: 84.1
Entry  Tue Jun 3 13:08:47 2025, Xuesi Ma, Update, ,  934.jpg933.jpg
We currently have the parts for a DB9 connector but need parts for a DB25 connector, where did we get the parts for the DB9 connector? We may be able
to use the same company for the DB25 connector.
Also need a cable for the connectors. Find a DB9 to DB9 cable in 1129, not sure if I can disassemble it and use just the cable.
Entry  Tue Jun 3 12:16:13 2025, Cynthia , Update, Interferometer Simulations, Point absorber simulation on radially averaged profile  update_6_3.pdf
 
Entry  Tue Jun 3 11:54:06 2025, Cece Ochoa, Update, , CE Cavity Design Update CE_Arm_Cavity_.pdf
Update on the design for the CE Cavity Mirrors
Entry  Tue Jun 3 11:50:08 2025, Pooyan, Update, CDS, CDS update 
There are three major issues with the lab's CDS system that should be addressed. They are ordered from the highest priority to the lowest.

CyMAC has stopped serving the fast channels (65k Hz)The channels are still there, and the data from the slow (16 Hz) channels is served correctly, but the fast data is not served. As a result, diagggui
Entry  Mon Jun 2 09:45:06 2025, Luke , Update, Scripts/Programs, Ringheater modeling Update 
Slides
I have added some slides to my meeting updates. The updates include: my choice in position and width, some figures I have added to my write up,
and what I think my immediate steps are to wrap up.
Entry  Tue May 27 12:52:22 2025, Xuesi Ma, Update, ,  6x
Using the configuration in section 2.11.1 in the Sorensen installation and operation manual (attached below), I'm able to remote control the Sorensen
power supply. 
I use DAC VEXC8 as the external voltage source and a breakout board to match the configuration of connector J3.
Entry  Mon May 26 23:24:33 2025, Michael, Update, Interferometer Simulations, Initial Monte Carlo Simulations for Toroidal Mirrors Project 
I've run an initial Monte Carlo simulation for statistical comparison of toroidal mirrors for the dual FROSTI TCS case. Below is the link to the slides.
slideshow
Entry  Mon May 26 11:15:28 2025, Luke, Update, Scripts/Programs, Update to optimization plots 
I have created some new optimization plots. I have also started on a model like the previous Desmos model, but in python. 
Slides
Entry  Wed May 21 14:40:38 2025, Xuesi Ma, Infrastructure, Cleanroom, Cleanroom Temperature 20250521_142051.jpg20250521_142220.jpg

    Date and Time: Around 2:20 PM on May 21, 2025
    Location and Temperature:
    
        Back of the room, around the working station: 85.5 °F
        Front of the room, around the doorway: 82.3 °F
Entry  Mon May 19 10:59:14 2025, Xuesi Ma, Infrastructure, ,  


  Status Update

  Previous Status:
  All Sorensen power supplies were turned off. The Cymac system was down (all chassis were offline).
  
    If you need more information or assistance in turning them back on, please contact Xuesi Ma.
  