The macor parts arrived and inspected today. These include:
-  Macor spacer (drawing: 
 LIGO_Redesign_Macor_Spacer_Drawing_v4.pdf  attached below), quantities: 40
-  No defects, damages observed 
 
-  Parts are free from grease/ machining fluid 
 
-  Wall thickness of 1 mm appear to provide sufficient stiffness to part 
 
-  Images of parts: 
 Macor_spacer_0.jpg, Macor_spacer_1.jpg  
  
 
-  Macor 5-40 UNC screw (drawing:  
 LIGO_Redesign_Macor_Screw_Drawing_v6.pdf  attached below), quantities: 20
-  One screw broke, location of break: should edge between head and shaft (see image  
 Macor_screw_5.jpg  )
  
-  All other screws look ok, no damage observed, clean surface overall 
 
-  Images: 
 Macor_screw_0.jpg , Macor_screw_4.jpg   
 
 
  | 
 | 
 | 
 | 
 
 | 
 | 
| 