ligo-ex ligo-ds
  Richardson Lab Experimental Log  Not logged in ELOG logo
Message ID: 734     Entry time: Tue Jul 14 21:23:40 2026
Author: Xuesi 
Type: Infrastructure 
Category: Cleanroom 
Subject: Cleanroom cleaning 

[Joshua, Cece, Ma, Mary, Abhi, Jacob, Dhatri]

The clean room (1119) was re-cleaned on Tuesday (7/14). A particle count measurement was performed on zones 1, 3, and 5. We noticed the burning smell again in 1129. As a precaution, we closed the two doors separating the three rooms.

Particle Count Measurements:

  • Zone 1:
    • 0.3 µm: 4873
    • 0.5 µm: 1041
    • 1.0 µm: 124
  • Zone 3:
    • 0.3 µm: 708
    • 0.5 µm: 83
    • 1.0 µm: 83
  • Zone 5:
    • 0.3 µm: 4165
    • 0.5 µm: 1916
    • 1.0 µm: 583
Attachment 1: 2026-07-14_21-08-30_cleanroom_chart.png  188 kB  | Show | Show all