Message ID: 556     Entry time: Mon Apr 21 16:56:42 2025
Author: Michael 
Type: Update 
Category: Interferometer Simulations 
Subject: Fixed Observed Squeezing Curve for Toroidal Mirror Case 
We've resolved the issue with the observed squeezing curve for the toroidal mirror case showing worse performance at lower frequencies and better performance at higher frequencies compared to the nominal case. This issue was caused by the beam parameter at the squeezer being fixed before changing the radii of curvature of the mirrors. This has been changed to be fixed after changing the mirrors, and we see an improvement in the toroidal mirror case.