ligo-ex ligo-ds
  Richardson Lab Experimental Log  Not logged in ELOG logo
Message ID: 387     Entry time: Thu Jun 27 11:09:14 2024
Author: Liu 
Type: Update 
Category: Scripts/Programs 
Subject: Straight edge STEP files and ray loss analysis 

Drawings and CAD models of the straight-edge designs are exported, and are visualized in SOLIDWORKS. Two are attached. One is a single edge of the evenly spaced polygon design with 16 edges, and the other is the 8x2 design, with two neighboring edges grouped together to replace the original single curved heater.

For the straight edge design in COMSOL, ray power detectors were placed at the heater's front surface. The irradiance is shown in figure. The amount of light rays deposited back to the heater is small when close to the center, where it is closer to the original ring. The ray power increases as we move further away from the center toward the edges. In addition, the total power integrated at the heater's front surfaces is about 21% of the original heater's emitted power. This could account for the power efficiency difference between the straight edge design and the ring design, as shown in plot for instance.

Attachment 1: edge_CAD_8x2_step.PNG  106 kB  | Show | Hide all | Show all
Attachment 2: edge_CAD_step.PNG  102 kB  | Hide | Hide all | Show all
edge_CAD_step.PNG
Attachment 3: Irradiance_frontheater.png  25 kB  | Show | Hide all | Show all
Attachment 4: Irradiance_profile.pdf  104 kB  | Show | Hide all | Show all
ELOG V3.1.3-7933898