ligo-ex ligo-ds
  Richardson Lab Experimental Log  Not logged in ELOG logo
Message ID: 218     Entry time: Thu Aug 31 12:56:29 2023
Author: Aiden 
Type: Update 
Category: VAC 
Subject: Vacuum Chamber Baking Update 
Took some more RGA data to see if the HC levels have further declined since bake 4 and it seems that it has started to plateau with August 29 160.7 e-10 Torrl/s and August 31 giving 158.4 e-10 Torrl/s. The pressure of the chamber before taking data was 5.1 e-8 Torr. I have attached an overlay of the data from August 29 and August 31. It seems that the extra two days has not noticeably changed the data and another bake will most likely be needed to meet LIGO's HC specifications. The pressure after leaving the RGA off for a bit was 5.9 e-8 torr and it was still slowly decreasing.
Attachment 1: bake4_230831_ArC.png  356 kB  | Hide | Hide all | Show all
bake4_230831_ArC.png
Attachment 2: bake4_230831_ArO.png  334 kB  | Show | Hide all | Show all
Attachment 3: bake4_230829_ArO.png  572 kB  Uploaded Thu Aug 31 13:59:51 2023  | Hide | Hide all | Show all
bake4_230829_ArO.png
ELOG V3.1.3-7933898