Message ID: 177     Entry time: Fri Jul 28 13:07:39 2023
Author: Shane, Aiden  
Type: Update 
Category: Cleanroom 
Subject: cleanroom cleaning and particle count 
[Aiden, Shane]

cleaning cleanroom and particle count

  • 11:08 am: started particle count
    • zone 3:
      • 0.3 u: 4198
      • 0.5 u: 1080
      • 1.0 u: 581
    • zone 4:
      • 0.3 u: 1247
      • 0.5 u: 623
      • 1.0 u: 415
  • 11:24 am: break for removal of vac chamber insulation (pictures attached), with counts before removal as seen above, and counts after removal/replacement for zone 3 as follows:
    • zone 3:
      • 0.3 u: 2993
      • 0.5 u: 415
      • 1.0 u: 207
  • 12:02 pm: began surface check and wipedown
  • 12:13 pm: started vacuuming the floor
  • 12:25 pm: finished vacuuming the floor
  • 12:26 pm: started mopping the floor
  • 12:32 pm: finished mopping the floor
  • 12:32 pm: started cleaning the buckets
  • 12:37 pm: started mopping with IPA wipes
  • 12:43 pm: finished mopping with IPA wipes
  • 12:45 pm: changed sticky floor mats
  • 12:47 pm: started particle count
    • zone 3:
      • 0.3 u: 2951
      • 0.5 u: 290
      • 1.0 u: 41
    • zone 4:
      • 0.3 u: 290
      • 0.5 u: 0
      • 1.0 u: 0
Attachment 1: image_50412289.JPG  1.612 MB  | Hide | Hide all | Show all
image_50412289.JPG
Attachment 2: image_50432769.JPG  1.955 MB  | Show | Hide all | Show all
Attachment 3: image_67126017.JPG  1.525 MB  | Hide | Hide all | Show all
image_67126017.JPG
Attachment 4: image_67163137.JPG  1.363 MB  | Hide | Hide all | Show all
image_67163137.JPG
Attachment 5: image_67168001.JPG  1.284 MB  | Hide | Hide all | Show all
image_67168001.JPG
Attachment 6: IMG_8427.jpeg  3.642 MB  | Show | Hide all | Show all
ELOG V3.1.3-7933898