ligo-ex ligo-ds
  Richardson Lab Experimental Log  Not logged in ELOG logo
Message ID: 113     Entry time: Thu Jun 1 14:41:36 2023
Author: Pamella 
Type: Update 
Category: FLIR 
Subject: FLIR project - Test without the black wall. 
[Pamella]
    Test without the black wall.
      General test:.
  • 11:15 am : Started running the code. Parameters: 0.11 A, 1.9V and focus distance around 0.55m.
  • 11:28 am : Started snapping the screen. Parameters: 0.12 A, 1.8V and 44.1 C .
  • First trying:
  • 01:18 pm : Started testing and collection data. Parameters: 0.09 A, 1.4V. Reference position: (0,0).
  • 01:28 pm : Started snapping the screen. Parameters: 0.10 A, 1.5V and 37.9 C. Reference position: (0,0).
  • Second trying:
  • 01:34 pm : Started testing and collection data. Parameters: 0.08 A, 1.4V. Reference position: (0,-0.10).
  • 01:44 pm : Started snapping the screen. Parameters: 0.09 A, 1.7V and 35.8 C. Reference position: (0,-0.10).
  • Third trying:
  • 01:50 pm : Started testing and collection data. Parameters: 0.08 A, 1.3V. Reference position: (0,-0.05).
  • 02:00 pm : Started snapping the screen. Parameters: 0.09 A, 1.4V and 35.4 C. Reference position: (0,-0.05).
  • Fourth trying:
  • 02:04 pm : Started testing and collection data. Parameters: 0.09 A, 1.3V. Reference position: (0,0.05).
  • 02:14 pm : Started snapping the screen. Parameters: 0.11 A, 1.6V and 41.7 C. Reference position: (0,0.05).
    Note: So today i tried collecting data for every possible position in Y (height) way for starting analyses and compares the triangles shapes. I realize maybe we get a problem because i keep the same time in every try but the final temperature and the parameters change every time, so i will try do a better system to keep the parameters equal, maybe i can wait the reflector be back to a normal temperature after every test or keep the system on all the time and just change the reflector position. I pretty sure this was the problem.
Attachment 1: thumbnail_IMG_7316.jpg  36 kB  | Show | Hide all | Show all
Attachment 2: AcquisitionImage(Jun-01-2023_14_14).jpg  23 kB  | Show | Hide all | Show all
Attachment 3: thumbnail_IMG_7320.jpg  47 kB  | Hide | Hide all | Show all
thumbnail_IMG_7320.jpg
ELOG V3.1.3-7933898